Technical diagram on page 35 30mm m aximum allow able sp ans mm sheet roof spacing mm rafter size 600 760 900 1000 1200 66 x 30 850 750 700 700 600 90 x 30 1200 1050.
Timber roof batten span tables.
Table 2l pergola or carport beams wind classifications n1 n2 n3 and c1 member size roof load width.
Loads are calculated in accordance with table 3 1 of as nzs 1170 1 2002.
These span tables apply only to flat roof and roof with a slope of up to 10 degrees.
All tables have been reproduced from as1684 2006 residential timber framed construction standard and assumes that a roof sheet mass of 10 kg m2 is added.
Ns not suitable general notes 1.
1 refer to general notes for information that is relevant for all span tables.
Span tables f7 rafters a maximum roof pitch of 25 degrees is assumed.
Maximum wind speed n2 refer to as4055 for site wind.
The high performance values of steel roof battens means they are an increasingly popular choice for reroofing or for new builds using tile roofs.
We supply 38 x 38mm or 28 x 38mm non structural timber battens for tile roofs.
2 for design parameters refer to figure 7 26.
Spacing should be interpreted as the centre to centre distance between adjacent parallel members.
For details of weights refer to about technical.
Timber battens for tile roofs must meet the requirements of as 1684 2 as 1684 3 or as 1720 1.
Stramit roof batten 0 48 0 48 mm g550 0 60 kg m stramit roof batten 0 55 0 55 mm g550 0 77 kg m stramit cyclonic roof batten 0 75 mm g550 0 98 kg m stramit ceiling batten 0 42 mm g550 0 37 kg m stramit wa ceiling batten 0 42 mm g550 0 34 kg m.
Maximum overhang of batten is 250 mm.
Design of single span rafters in roofs in houses office buidlings schools and other structures.
Note that spanman automatically calculates the weight of roof battens and adds it to the roof weight.
Required size for a given span.
Wind classification n1 n2.
Timber queensland limited technical data sheet 19 pergolas and carports revised march 2014 page 3 pergola or carport beams tables 2l and 2h list the sizes and spans for pergola or carport beams in low wind speed and higher wind speed areas.
Lintel span sheet roofing tiled roofing roof load width rlw mm 1500 2100 4500 7500 1500 2100 4500 7500 maximum span of lintel mm 90 x 35 600 2000 1800 1400 1200.
Table assumes a maximum flooring mass of 40kg.
Refer to as1684 tables for other overhang spans.
Timber to be covered these span tables do not apply to timber which is fully exposed to the elements.
Construction details should be in accordance with as1684 2.
Joists crippled over supports shall be considered as single span joists.
Member tables for seasoned timber stress grade f17.
Pergola rafter spans for 600 mm and 900 mm spacing.